Ventilator 590 P

No Comments on Ventilator 590 P

ventilator
ICU Ventilator  Shangrila 590 P

Harga  :  Rp. 205.000.000

Merek  :  AeonMed

Brosur Ventilator 590 P
  • Volume Controlled (VCV), Assist/Control
  • Pressure Controlled (PCV), Assist/Control
  • Pressure Regulated Volume Control (PRVC), Assist/Control
  • Synchronized Intermittent Mandatory Ventilation (SIMV)
    Volume-controlled breaths (V-SIMV)
    Pressure-controlled breaths (P-SIMV)
    Pressure Regulated Volume Control- controlled breaths (PRVC-SIMV)
  • Bi Level Ventilation (BIVENT) *Option
  • Spontaneous Ventilation (SPONT)
  • Continuous Positive Airway Pressure (CPAP)
  • Non Invasive/CPAP (NIV/CPAP) *Option
  • Non Invasive/Pressure Controlled Ventilation (NIV/PCV) *Option
  • Combined: VCV+SIGH, SIMV (VCV)+Pressure Support (PS), IMV (PCV)+PS, SIMV (PRVC)+PS, BIVENT+PS, NIV/CPAP+PS, SPONT+PS
  • Tidal volume : 20~2500ml
  • Respiratory rate : 4~100bpm (used in VCV & PCV & PRVC) 1~40bpm (used in V-SIMV & P-SIMV & PRVC-SIMV)
  • Inspiration time : 0.1~12s
  • Inspiratory pause time : 0~4s
  • FiO2 : 21%~100%
  • Trigger sensitivity : Pressure (-2~0kPa, above PEEP) Flow (0.5~20LPM, with base flow)
  • PEEP : 0~5kPa
  • Psupport : 0~6kPa
  • Pcontrol : 0.5~6kPa
  • E-sense : 5%~80%
  • Suction : Maximum 2min
  • Inspiratory hold : Yes
  • Expiratory hold : Yes
  • Manual inspiration : Yes
  • Waveform freeze : Yes
  • Nebulizer : 30 minutes
  • Key lock : Yes
    Monitoring
  • Pressure values : Pplat,????Ppeak, Pmean, PEEP
  • Volume/Flow values : VTI, VTE, MV, MVspont
  • Time values : ftotal, fspont, I:E
  • Oxygen monitoring : O2 sensor
  • Real time curves : Pressure-Time, Flow-Time, Volume-Time, Pressure-Volume loop, Flow-Volume loop
  • Respiratory mechanics, dynamic and static compliance, resistance, auto PEEP
    Alarm
  • MV high, MV low, Paw high, Paw low, Peep High,????Peep low,????Airway pressure continue high, VTE low, VTE high, fspont high, Tapnea, FiO2 low, FiO2 high, Power supply failure, Nebulizer on, Battery low, Battery exhausted, Air supply failure, O2 supply failure, Air & O2 supply failure, Fan Block, Pipe block, Circuit disconnected
    Technical data
  • Screen : 12.1”TFT color touch screen (detachable)
  • Gas supply : O2, Air (All gas must be medical level), 0.28~0.6MPa
  • Power supply : AC110~240V, 50Hz-60Hz, 65VA
  • Internal battery : >1 hour work time
  • Maximum security pressure : ?8kPa
  • Compliance : ?4mL/100Pa
  • Noise : ?65dB (A)
  • Communication interfaces : RS232 port, VGA port, Nurse call
  • Dimensions (H×W×D) : 400×303×250 mm
  • Weight : 15kg