Aeonmed 7500 A

No Comments on Aeonmed 7500 A

Aeon 7500A
Mesin Anesthesi AEON 7500A

Harga : Rp.

Merek  :  Beijing Aeonmed

Brosur Aeonmed 7500 A
  • Mode : Semi-Open, Semi-Closed, Closed System
  • 10,4″ TFT Display monitoring system
  • Vaporizer dilengkapi dengan system interlock, dengan pilihan Halothane, Isoflurane, Sevoflurane, Enflurane
  • For Adult and Pediatric
  • Gas flow control system with interlock
  • Precise flowmeter with Low FLow Range (0-1L/Min) and high accuracy (o,05L/Min) meeting low flow requirement.
  • Flow joint control device, make O2 and N2O can be proportionally regulated, providing >25% oxygen even with N2O control knob fully open
  • Power Supply :
    Voltage : 100 – 240 V AC, 50Hz / 60Hz
    Input power : 50 Watt
  • Gas Supplies :
    Pipeline/Medical gas color codes
    Medical Air : Black
    Oxygen : White
    Nitrous oxide : Blue
  • Flowmeters :
    Flow ranges : cascade flow tubes
    Medical Air : 0.1 – 10 L/Min
    Oxygen : 0 – 1 L/min dan 1 – 10 L/min
    Nitrous oxide : 0 – 1 L/min and 1 – 10 L/min
    Flowmeter tube accuracy is ± 2.5% of full scale reading
    Flow joint control device for O2 and N2O can be – proportionally regulated providing FiO2?25%.
  • Gas Pressures :
    Pipeline supplies : 0.4 Mpa
    Supply pressure variation : 0.1 Mpa
    Oxygen Failure Warning Device : Whistle
  • Oxygen Flush :
    The system supplies 35 – 75 L/min when fully depressed
  • Valve :
    Safety valve : 6 kPa
    Spill-over valve pressure : 0.2 kPa – 0.35 kPa
  • Volume and Weight :
    Overall size : 656 mm (W) x 1350 mm (H) x 622 mm (D)
    Weight : Approximately 148 Kg.
  • Vaporizer :
    Vaporizer type : Halothane, Enflurane, Isoflurane, Sevoflurane
    Liquid capacity :
    – Volume from minimum to maximum mark : 250 mL
    – Volume retained by wick system : 40 mL
    Flow range :
    – 0.2 to 15 L/min
    Concentration : 0 – 5 %
    Interlock system safety
    Drager plug in compatible
    Dimension : 230 mm x 120 mm x 210 mm
    Weight : 6.2 kg
  • Ventilator MV300
    Performance of airway sistem for ventilator :
    Safety pressure of the airway system : Not more than 6 kPa
  • Ventilation Mode :
    Volume Mode, Pressure Mode, SIMV Mode, Manual Mode
    Patient Type Adult, Paediatric
  • Ventilation Performance :
    Respiration frequency : 4 – 100 times/min, ±2times/min
    I:E Ratio ; 1:0.5 – 1:8
    Tidal Volume : 0.50 – 1500mL
    Minute Volume : 3 to 75 L/min
  • Display Mode
    10,4″ TFT Screen Display
    Monitor Performance :
    Tidal Volume, Airway Pressure, Breath Rate, FiO2,
    Airway Pressure Waveform, Airflow Pressure Waveform
  • Alarm Performance :
    High Airway Pressure, Low Airway Pressure, Power Off,
    Breath Rate, Minute Volume High / Low, O2 Concentration
    High / Low, Mains Failure.
    Silence : ?120 second